banner

Products

Home Flow meter Gas Roots/Waist Wheel Flow Meter LLGQ Gas Roots /Waist Wheel Flow Meter

New Products

  • Gas Roots (waist wheel) flow meter

    Smart gas Roots (waist wheel) flow meter Intelligent gas waist wheel (Roots) flowmeter is a new generation flowmeter that integrates flow, temperature, and pressure detection functions, and can automatically compensate for temperature and pressure. Gas is a compressible fluid, and its volume value is closely related to temperature and pressure. In order to unify standards for both parties, it is necessary to convert the actual volume into a standard volume under reference conditions (101.325 kPa 20°C). In order to achieve this purpose, the smart gas waist wheel flowmeter can accurately correct the volume of gas; it is an ideal instrument for gas measurement in urban gas, petroleum, chemical, electric power, metallurgy and other industries. more

  • Portable Ultrasonic Flow Meter

    TUF Series Portable Ultrasonic Flow Meter The TUF series ultrasonic flow meter utilizes the principle of low voltage and multiple pulsation time difference, adopts the high-precision and ultra-stable differential transmission of double-balanced signals and differential receiving digital detection technology to measure the acoustic wave transmission time in both the downstream and counter-current directions, and calculates the flow rate according to the time difference.It has the characteristics of good stability, small zero drift, high measuring accuracy and high anti-interference of measuring range over wide. more

  • Intelligent Type Flow Meter

    LDB Intelligent Type Electromagnetic Flow Meter The LDB intelligent type electromagnetic flow meter consists of a sensor and a converter. It is based on Faraday's law of electromagnetic induction, which is used to measure the volume flow of conductive liquid with conductivity greater than 5μs/cm. It is an inductive meter for measuring the volume flow of conductive medium. In addition to measuring the volume flow of general conductive liquid, it can also be used to measure the volume flow of strong corrosive liquids such as strong acid and alkali and uniform liquid-solid two-phase suspension liquid such as slurry, pulp and paper pulp. more

  • Thermal Mass Gas Flow Meter

    LKQ Thermal Gas Mass Flow Meter LKQ thermal gas mass flow meter is a mass flow measurement and monitoring meter,which can detect  air, natural gas, hydrogen, oxygen, chlorine, nitrogen and ammonia, ammonia, coal gas, phosgene, flue gas and various chemical mixtures, without pressure and temperature compensation. It can be widely used in petroleum, chemical, metallurgy, electric power, water treatment, paper, food, medicine, cement, textile and various production, scientific research units for process control and gas flow measurement. Widely used in: flow measurement of steel plant, coking plant gas. more

  • Gas Flow Meter

    LLGQ Gas Roots /Waist Wheel Flow Meter The gas roots flowmeter has been used as a volumetric meter for more than 100 years.  With the features such as high precision, wide range, small volume, light weight, convenient installation and maintenance, reliable and durable service life, it is widely used in natural gas, coal gas, air and other gas flowmeters.It is an ideal flowmeter device for urban gas, oilfield chemical, scientific research and other departments at home and abroad. more

  • Gas Turbine Meter

    High Precision Gas Turbine Flow Meter Gas turbine flowmeter is a new generation of high precision, high reliability gas precision measuring meter integrating temperature, pressure, flow sensor and intelligent flow totalizer developed by the advanced technology of flow meter at home and abroad, optimized by theories of gas mechanics, fluid mechanics and electromagnetics, which has excellent low pressure and high pressure metering performance. more

  • Mass Vortex Flow Meter

    LUGK Multi Variable Type Vortex Flow Meter Mass vortex flowmeter, simple to install. Connection mode: flange and clamping connection. It has superior reliability and stability due to no movable part, and the detecting portion has only a simple configuration of the vortex generator. Low pressure loss, no leakage point, and high safety performance. Robust sensor construction for high temperature (up to 3500 ° C), high pressure fluid. more

  • Steam Gas Vortex Flow Meter

    LUGC Steam Gas And Liquid Insert Type Vortex Flow Meter The Insert Type vortex flowmeter is simple in structure and can be made into online installation type.Applicable to large diameter gas, steam flow measurement, etc.Easy installation, no pipe design. more

  • Vortex Flow Meter

    LUGB Flow Instrumentation Vortex Flow Meter The vortex flowmeter is a speed type flow instrument which has a wide range of uses. It is suitable for flow metering, measurement and control of liquids, steam and most gases. more

LLGQ Gas Roots /Waist Wheel Flow Meter

The gas roots flowmeter has been used as a volumetric meter for more than 100 years.  With the features such as high precision, wide range, small volume, light weight, convenient installation and maintenance, reliable and durable service life, it is widely used in natural gas, coal gas, air and other gas flowmeters.It is an ideal flowmeter device for urban gas, oilfield chemical, scientific research and other departments at home and abroad.

  • Product Origin:

    China
  • Shipping Port:

    Huangpu port
  • Lead Time:

    Spot
  • MOQ:

    1
Product Details

Features

■ It integrates high-precision temperature, pressure, flow sensor and intelligent volume corrector to detect the temperature, pressure and flow of the measured gas and perform automatic flow track and compensation and compression factor correction.

■Use advanced microcomputer technology and high-performance integrated chip, it has powerful functions and superior performance.

■The circuit uses the surface mount technology, with compact structure, strong anti-interference ability and high reliability.

■Use advanced micro-power high-tech, the whole machine has low power consumption, that is, it can run with built-in battery for long time, and can be operated by external power supply.

■ According to the flow frequency signal, the meter factor can be automatically corrected linearly in five segments, to improve the accuracy of the meter.

■ With fault self-diagnosis and alarm function, high reliability, LCD display, clear and intuitive, easy to read.

■The flowmeter has a pulse signal output, and can also output 4~20mA standard analog signal according to user needs.

■ The meter has its own real-time database, and it forms a meter reading network through R5-485 communication interface to facilitate centralized data collection and real-time management.

■Use advanced micro-power technology, low power consumption. It can run for more than five years using built-in battery. It displays the flow value locally with various signal output functions to meet the needs of different fields and systems. It uses EEPROM data storage to save user parameters, manufacturer parameters and a certain history.

■ Use high-contrast three-line LCD display for displaying date, standard cumulative flow, standard instantaneous flow, medium temperature, pressure, and battery voltage.

■ With real-time data storage function, it can avoid data loss when battery is replaced or suddenly power down. In the power-off state, internal parameters can be permanently saved.


Flowmeter Selection

                                                                                                                                                      Table 1

Model

Description

LWGQ-

Mechanical gas roots flowmeter

LWGQD-

Intelligent gas roots flowmeter

Caliber

25

DN 25mm

40

DN 40mm

50

DN 50mm

80

DN 80mm

100

DN 100mm

150

DN 150mm

200

DN 200mm

Range

A

Little range

B

Medium range

C

Big range

Accuracy grade

01

Class 1.0

02

Class 1.5

Output model

A

Pulse output, IC card pulse output, alarm output

B

4-20mA two-wire current, pulse output, IC card pulse output, alarm output

C

4-20mA three-wire current, pulse output, IC card pulse output, alarm output

Explosion-proof grade

N

Standard type, no explosion-proof

E

Explosion-proof type, ExdIICT6


Flowmeter Outline Dimension

The flowmeter installation dimensions are shown in Fig.1 and Table 2. The flange is in accordance with GB/T9119-2000.

Ⅰ type roots flow meter installation

Ⅱ type roots flow meter installation

Flowmeter appearance and install dimensions                                                                                                Table 2

Model specification

Nominal diameter

DN

Inlet and outlet direction

A

(mm)

B

mm

C

mm

W

mm

H

mm

Structure type

Weight

kg

Flange

C1

n-d

LLGQ-20A

25

Entering at top and leaving at bottom

235

G1

88

105

240

3.5

70

4-M10

LLGQ-40A

40

Entering at top and leaving at bottom

285

G1/

111

105

240

4.6

90

4-M12

LLGQ-40B

40

Entering at top and leaving at bottom

307

G1/

122

105

240

5

90

4-M12

LLGQ-50A

50

Entering at top and leaving at bottom

375

167

134

167

190

12

φ110

4-M12

LLGQ-50B

50

Entering at top and leaving at bottom

375

167

134

167

190

12

φ110

4-M12

LLGQ-80A

80

Entering at top and leaving at bottom

450

167

169

167

190

15

φ150

4-M16

LLGQ-80B

80

Entering at top and leaving at bottom

502

167

196

167

190

17

φ150

4-M16

LLGQ-80C

80

Entering at top and leaving at bottom

465

205

179

235

245

25

φ150

4-M16

LLGQ-100A

100

Entering at top and leaving at bottom

564

205

230

235

245

60

φ170

4-M16

LLGQ-100B

100

Entering at top and leaving at bottom

564

205

230

235

245

60

φ170

4-M16

LLGQ-100C

100

Entering at top and leaving at bottom

655

205

274

235

245

60

φ170

4-M16

LLGQ-150A

150

Entering at top and leaving at bottom

556

φ265

234

450

460

III

72

φ225

8-M16

LLGQ-150B

150

Entering at top and leaving at bottom

696

φ265

304

450

460

III

85

φ225

8-M16

LLGQ-150C

200

Entering at top and leaving at bottom

847

φ320

380

450

460

III

90

φ280

8-M16


Flowmeter installation precautions and requirements

■ Before selecting the flowmeter, the appropriate model and specifications shall be selected according to the pressure, flow, temperature and process requirements of the metered gas. (see “Flow Conversion”for the calculation method, ).

■ Before installing the flowmeter, the inlet and outlet packages shall be removed. It is necessary to prevent the particulate impurities from entering the measuring chamber. For example, the surface of the measuring chamber is coated with anti-rust oil, which can be cleaned with gasoline or kerosene, and the impurities in the pipe are strictly removed. A filter shall be installed upstream of the flowmeter to prevent rust, welding slag and other impurities from entering the metering chamber.

■When the flowmeter is installed, the rotor axis shall be kept as level as possible regardless of whether the inlet and outlet are vertical or horizontal.

■ When the gas pressure fluctuation range is large, in order to ensure the measurement accuracy, a regulator shall be installed upstream of the flowmeter.

■ In order to prevent rust, welding slag and other impurities in the newly installed pipe from entering the flowmeter, users shall first install the transition pipe on the installation position of the flowmeter.After venting for a period of time, make sure that there are no large particles of impurities, then install the flowmeter. When installing the flowmeter, make sure that the flowmeter center is aligned with the pipe center, no misalignment, and the flowmeter is not affected by external forces (including axial and tangential directions ).

■ When installing the flowmeter vertically.  It is recommended that the flow direction of the gas is entering at top and leaving at bottom. In special cases, it can perform entering at bottom and leaving at top,entering at left and leaving at right.However, special descriptions are required when ordering. The standard product of the flowmeter is entering at top and leaving at bottom. The front and rear valves and bypass pipes should be installed when installing the flowmeter to ensure that there is no need to stop the air during maintenance. Fig.2, Fig.3, and Fig.4 show the typical system diagrams for entering at top and leaving at bottom,entering at bottom and leaving at top,entering at left and leaving at right.entering at left and leaving at right.Tpical system diagrams for three flowmeter pipe installation  for reference.

Flow meter installation piping system diagram

■ The pipes and fittings of each part of the flowmeter installation must be properly sized, and the flowmeter body must not be subjected to abnormal external forces.

■ After the flowmeter is installed, inject the lubricating oil (GB486~65 high-speed oil H5) from the oil filling port to the oil window center line (note that you cannot add more).

■ Perform regular or irregular inspection during use to ensure sufficient and clean lubricant.If the lubricant is black or the oil level is higher than the center line of the oil window,  it indicates the lubricant is deteriorated or has impurities.In this case, replace the lubricant. If the oil level is 3mm below the center line of the oil window, it indicates the loss of lubricating oil and needs to be added to the center line of the oil window. When filling the lubricating oil, it must close the front and rear valves of the flowmeter, and after the gas is drained, then the lubricating oil is added.

■When the flowmeter is in operation, all valves shall be opened and closed slowly to prevent the strong impact of the airflow and damage the flowmeter.

■After the flowmeter is in operation for a period of time, if the pressure drop of the filter is increased, the filter shall be cleaned or the filter medium shall be replaced. If the pressure drop of the flowmeter is increased, and the starting flow rate is increased, and it can flush the metering chamber with clean gasoline or kerosene.

■ When the flowmeter is deactivated for a long time, it should empty the lubricating oil , and the metering chamber shall be flushed with gasoline, then the inlet and outlet shall be sealed and placed in a dry place.

■ When the flowmeter is used to measure city gas (natural gas, artificial gas, etc.), its impurity content shall meet the content standard of China's “Urban Gas Design Code”(GB50028-93).

A free consultation

Email us with any questions or inquiries or use our contact data. We would be happy to answer your questions.

Related Products
 Gas Roots Flow Meter
LLGQ Intelligent Gas Roots Flow Meter

High precision, wide range of measurement, small volume, light weight, easy installation and maintenance, reliable use and pressure life and other characteristics of gas Roberts flow meter, widely applicable to natural gas, coal gas, inert gas, air and other gas flow measurement.

Gas Roots (waist wheel) flow meter
Smart gas Roots (waist wheel) flow meter

Intelligent gas waist wheel (Roots) flowmeter is a new generation flowmeter that integrates flow, temperature, and pressure detection functions, and can automatically compensate for temperature and pressure. Gas is a compressible fluid, and its volume value is closely related to temperature and pressure. In order to unify standards for both parties, it is necessary to convert the actual volume into a standard volume under reference conditions (101.325 kPa 20°C). In order to achieve this purpose, the smart gas waist wheel flowmeter can accurately correct the volume of gas; it is an ideal instrument for gas measurement in urban gas, petroleum, chemical, electric power, metallurgy and other industries.

MF5806 Digital Oxygen Flow Meters
MF5806 Series Digital Oxygen Flow Meters

MF5806 series digital oxygen flow meter inhaler is produced by MEMS flow sensor chip of MEMS system developed by our company.It is suitable for medical center oxygen supply system, emergency oxygen supply and hypoxia inhalation.LCD digital display provides instantaneous flow, cumulative flow and oxygen time, intuitive and simple.It can help doctors determine more accurately how much oxygen a patient is getting.

Standard Orifice Meter Throttle Device
LG Standard Orifice Meter Throttle Device

There are several methods to measure the flow rate of medium through pipelines, but the most widely used and common one is differential pressure flow meter.It is composed of the throttle device and the differential pressure gauge or the throttle device and the differential pressure transmitter together with the secondary table.Typical application of flow throttling device: medium and high velocity gas such as steam and compressed air.

Precise Liquid Flow Meter
LWGH High Pressure Type Liquid Turbine Flow Meter

LMGH series high pressure type liquid turbine flowmeter is a special high pressure flowmeter which is designed for high pressure fluid industry such as hydraulic equipment, engineering machinery, chemical industry, etc. The outer housing is made of stainless steel, with simple structure,optimized structure, and high pressure butt flange clamping or high pressure threaded connection.

Portable Ultrasonic Flow Meter
UF200 Portable Ultrasonic Flow Meter

Introduction:  UF 200 is a full function handle transfer time ultrasonic flow meter. No matter you want to quickly verify the flow reading of another meter or to data log flow system values over an extended time period, the Voxtmeter UF200 is the suitable tool. The UF200 portable meter has the clamp on transducers no tapping or cutting is required, just clamp outside of the pipe. The meter can be easily moved and installed in different pipe and convenient to carry site to site.Its portability makes it an excellent choice formeasuring flows throughout the plumbing infrastructure to verify sensor, pump andvalve performance.1. Easy to install, reduced installation time and 

 Gas Roots Flow Meter
LLGQ Intelligent Gas Roots Flow Meter

High precision, wide range of measurement, small volume, light weight, easy installation and maintenance, reliable use and pressure life and other characteristics of gas Roberts flow meter, widely applicable to natural gas, coal gas, inert gas, air and other gas flow measurement.

UF 1000 Wall Mounted Ultrasonic Flowmeter
High-Precision UF 1000 Wall Mounted Ultrasonic Flow Meter

UF 1000 is an economical jet - lag ultrasonic flow meter specially designed for water.Compared with other ultrasonic flow meters on the market, it has the characteristics of high reaction rate, low power consumption and high stability. In addition, it also continues the TGA technology independently researched.

LZ Metal Tube Float Flowmeter
LZ Metal Tube Float Flow Meter

LZ series of metal tube float flowmeter is based on the float position measuring a variable area flow meter, adopts full metal structure, the concept of Modular design, because of its small size small pressure loss, large range than (10:1), installation, maintenance is convenient wait for a characteristic, therefore widely used in various industries are complex, bad environment, low for small flow velocity, the conditions of all kinds of harsh medium flow measurement and process control.

MF5000 Gas Flow Meters
MF5000 series Gas Mass Flow Meters

ME5000 series gas mass flowmeter is the company combined with micro-electromechanical system (MEMS) flow sensor chip technology and many years of computer adaptive technology experience, the development of intelligent electronic gas mass flowmeter, the main technical performance in the international leading level, with high sensitivity, high precision, large range ratio and other characteristics.

LF2600 Liquid Flow Sensors
LF2600 Series Liquid Flow Sensors

The LF2600 series liquid flow sensor adopts the MEMS flow sensor technology and sensor packaging technology of Guangzhou Nan Kong Automation Equipment Co.,Ltd., which integrates the thermal flight time (TOF) and thermal sensing principles.

MF5200 Oxygen Flow Meters
MF5200 Series Oxygen Flow Meters

MF5200 series oxygen mass flowmeter is specially designed for the hospital center oxygen supply system.The flowmeter has detachable display, RS485 network communication interface and user-defined alarm function to better achieve network transmission and traffic monitoring.

© Copyright: 2024 Hubei Nan Kong Instrument Technology Co.,Ltd..All Rights Reserved.

Chat now

Live Chat

    Email us with any questions or inquiries or use our contact data. We would be happy to answer your questions.